| Sign In | Join Free | My entremaqueros.com | 
 | 
Brand Name : Winston/OEM
Model Number : WCM1
Certification : CE,ROSH
Place of Origin : China,Zhejiang
MOQ : 1PCS
Price : USD10 to USD450/PCS
Payment Terms : T/T,L/C,Paypal,Online Payment,RMB/USD
Supply Ability : 10000PCS/Month
Delivery Time : 3-15days after get payment.
Packaging Details : Export standard carton box
Material : Plastic
Current : from 6A to 1600A
Poles : 3,4
Frequency : 50/60HZ
Rated operating voltage : 400V or below
OEM : Yes
Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent
Main Technical Specification(table1)
| Type | Rated | Polenum-ber | Ratedinsui-atingvolt-age(V) | Rated | Arcing- | Ultimate | Servies | Operation | Utiliza-tioncat-egory | |
| Load | Unload | |||||||||
| WCM1-63L | (6),10 | 3, 4 | 500V | 400V | 0 | 25 | 18 | 1500 | 8500 | A | 
| WCM1-63M | 0 | 50 | 35 | |||||||
| WCM1-100L | (10),16 | 800V | 0(≤50) | 35 | 22 | |||||
| WCM1-100M | 0(≤50) | 50 | 35 | |||||||
| WCM1-100H | 0(≤50) | 85 | 50 | 1000 | 7000 | |||||
| WCM1-225L | 100,125 | ≤50 | 35 | 22 | ||||||
| WCM1-225M | ≤50 | 50 | 35 | |||||||
| WCM1-225H | ≤50 | 85 | 50 | 1000 | 4000 | |||||
| WCM1-400L | 225,250 | ≤50 | 50 | 35 | ||||||
| WCM1-400M | ≤100 | 65 | 42 | |||||||
| WCM1-630L | 400,500 | ≤100 | 50 | 35 | ||||||
| WCM1-630M | ≤100 | 65 | 42 | |||||||
| WCM1-630H | ≤100 | 100 | 65 | |||||||
| WCM1-800M | 630,700 | 3 | ≤100 | 75 | 50 | |||||
| WCM1-800H | ≤100 | 100 | 65 | |||||||
| WCM1-1250M | 1000,1250 | ≤100 | 100 | 65 | ||||||
| WCM1-1250H | ≤100 | 125 | 75 | |||||||
| WCM1-1600M | 1600 | ≤100 | 150 | 80 | ||||||
 Note: 6A without thermal protection
 The N-pole of four-poles breaker is sited at the right side of the product has four types:
 Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles.
 Type B: Without current trip-release on N pole which closing and opening with the other poles.
 Type C: With current trip-release which closing and opening with the other three poles.
 Type D: With current trip-release which making all the time not closing and opening with the other three poles.
 
 Protection Characteristic
 The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker).
 
 
 Table2
| Rated current of release (A) | Thermodynamic release( ambient temperature ) land +40°C marine +45°C | Operating current of magnetic release (A) | |
| 1.05In(cold state) Inoperative time(h) | 1.30In(heat state) Operative time(h) | ||
| 10≤In≤63 | ≥ 1 | < 1 | 10In±20% | 
| 63 | ≥ 2 | < 2 | |
| 100≤In≤800 | ≥ 2 | < 2 | 5In±20% 10In±20% | 
 
 Table3
| Rated current | Thermodynamic release ( ambient temperature ) land +40°C marine +45°C | Operating current of magnetic release (A) | |||
| of release (A) | 1.0In(cold state) non-trip time(h) | 1.20In(heat state) trip time (h) | 1.50In(heat state) trip time (h) | 7.2In(cold state) trip time(h) | |
| 10 ≤ In ≤ 225 | ≥ 2 | <2 | ≤ 4min | 4s < Tp ≤ 10s | 12In±20% | 
| 225 ≤ In ≤ 630 | ≤ 8min | 6s < Tp ≤ 20s | |||
 
 Accessories of Circuit breaker
 1 The external accessories of the breaker
 Motor-driven operation device
 1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)

 
 Code description: SB1SB2stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
 Voltage rating: AC50Hz 230V 400V DC 220V
 2) Wiring diagram of type CD motor-driven operation device (fitting AM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)

 
 
 Code description: SB1SB2stand for push button. (provided by users themselves) "X" stands for line connection terminals
 Voltage rating: AC50Hz 230V 400V DC 220V
 
 
 
 Rotary handle operation device
 The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.

 
 4.2 Release pattern and accessories code
 
 SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact
| Release patternand accessories code | Name/Type | WCM1-63, 100, 225 | WCM1-400 | WCM1-630 | WCM1-800 | 
| 200, 300 | No accessories | 200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection) | |||
| 208, 308 | Alarm contact |  |  |  |  | 
| 210, 310 | Shunt release |  |  |  |  | 
| 220, 320 | Auxiliary contact |  |  |  |  | 
| 230, 330 | Under-voltage release |  |  |  |  | 
| 240, 340 | Shunt release Auxiliary contact |  |  |  |  | 
| 250, 350 | Shunt release Under-voltage release |  |  |  |  | 
| 260, 360 | Two group of auxiliary contact |  |  |  |  | 
| 270,370 | Under-voltage release Auxiliary contact |  |  |  |  | 
| 218, 318 | Shunt release Alarm contact |  |  |  |  | 
| 228, 328 | Alarm contact Auxiliary contact |  |  |  |  | 
| 238, 338 | Under-voltage releaseAlarm contact |  |  |  |  | 
| 248, 348 | Shunt release, Alarm contact,Auxiliary contact |  |  |  |  | 
| 268, 368 | Two group of auxiliary contact,Alarm contact |  |  |  |  | 
| 278, 378 | Shunt release, Alarm contact, Under-voltage release |  |  |  |  | 
 According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).
 
 Under-voltage release
 Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V

 
 When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.
 
 
 Shunt release
 Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.

 
 Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.
| Alarm contact | |||
| The position of the breaker in "off" or "on" |  | ||
| The position of the breaker in "free trip" (alarm) | 
 | 
  
| Auxiliary Contact | ||
| When the breaker is in"off" |  | For the breaker with frame current400A and above | 
|  | For the breaker with frame current225A and below | |
| When the breaker is in"on" | When the breaker is in "off", the contacts switch from "close" to "open".When the breaker is in "off",the contacts switch from "open"to close" | |
|   | 
| Custom Molded Case Low Voltage Circuit Breaker For Changing Motor Infrequent Images | 
 Economic Small Earth Leakage Circuit Breaker Molded Case Plastic NF-CW
                                                                                    
                        
                        
                        
                                                            Economic Small Earth Leakage Circuit Breaker Molded Case Plastic NF-CW
                                                    
                        
                     400 Volt CM1 Molded Case Circuit Breaker , Electronic Circuit Breaker 6A - 1600A
                                                                                    
                        
                        
                        
                                                            400 Volt CM1 Molded Case Circuit Breaker , Electronic Circuit Breaker 6A - 1600A
                                                    
                        
                     AC 690V Molded Case Circuit Breaker NS Short Circuit / Overload Protection
                                                                                    
                        
                        
                        
                                                            AC 690V Molded Case Circuit Breaker NS Short Circuit / Overload Protection
                                                    
                        
                     NS Series Moulded Case Adjustable Circuit Breaker Leakage Protection
                                                                                    
                        
                        
                        
                                                            NS Series Moulded Case Adjustable Circuit Breaker Leakage Protection
                                                    
                        
                     WCM1 Molded Case Circuit Breaker 60HZ , Motor Circuit Breaker IEC60947-2
                                                                                    
                        
                        
                        
                                                            WCM1 Molded Case Circuit Breaker 60HZ , Motor Circuit Breaker IEC60947-2
                                                    
                        
                     OEM Thermal Molded Case Magnetic Circuit Breaker 3 Pole M611 1.6A - 20A
                                                                                    
                        
                        
                        
                                                            OEM Thermal Molded Case Magnetic Circuit Breaker 3 Pole M611 1.6A - 20A
                                                    
                        
                     Winston Plastic Moulded Case Circuit Breaker 220V Short Leading Time 3VE
                                                                                    
                        
                        
                        
                                                            Winston Plastic Moulded Case Circuit Breaker 220V Short Leading Time 3VE
                                                    
                        
                     Molded Case Circuit Breaker , 3 Pole / 4 Pole Circuit Breaker Earth Leakage
                                                                                    
                        
                        
                        
                                                            Molded Case Circuit Breaker , 3 Pole / 4 Pole Circuit Breaker Earth Leakage
                                                    
                        
                     Steady 3P MCCB Molded Case Circuit Breaker Reliable 950V 12.5A -1250A
                                                                                    
                        
                        
                        
                                                            Steady 3P MCCB Molded Case Circuit Breaker Reliable 950V 12.5A -1250A
                                                    
                        
                     WNS-100 Black 3 Pole MCCB Electrical Circuit Breaker 500V Fire Proof
                                                                                    
                        
                        
                        
                                                            WNS-100 Black 3 Pole MCCB Electrical Circuit Breaker 500V Fire Proof